AC size / BTU calculator

Two modes. For a window or portable unit, we use the official ENERGY STAR room air-conditioner chart and ENERGY STAR’s published adjustments. For a whole house, we show a wide planning range by climate zone and tell you to get a Manual J before you buy.

The space

ENERGY STAR’s chart assumes 8 feet. Height scaling is a planning adjustment, not an official ENERGY STAR factor.
ENERGY STAR: add 600 BTU/hr for each person beyond two.

Enter the square footage to see a BTU and tonnage estimate.

How this is calculated

Room mode uses ENERGY STAR’s capacity chart for an 8-foot ceiling, then applies ENERGY STAR’s official adjustments: −10% if heavily shaded, +10% if very sunny, +600 BTU/hr per person beyond two, and +4,000 BTU/hr in a kitchen. If you enter a ceiling height other than 8 feet, we scale by volume (height ÷ 8) and label that as unofficial.

Whole-house mode multiplies floor area by a wide BTU-per-square-foot band for your IECC-style climate zone, then applies planning factors for insulation, sun, and ceiling height. Those per-square-foot bands are rules of thumb, not a DOE or ENERGY STAR table and not ACCA Manual J. Orange County is IECC zone 3B; the optional coastal vs inland split is a qualitative planning nudge inside zone 3.

ENERGY STAR room air-conditioner chart

Area to be cooled (sq ft)Capacity (BTU/hr)Tons
100–1505,0000.42
150–2506,0000.50
250–3007,0000.58
300–3508,0000.67
350–4009,0000.75
400–45010,0000.83
450–55012,0001.00
550–70014,0001.17
700–1,00018,0001.50
1,000–1,20021,0001.75
1,200–1,40023,0001.92
1,400–1,50024,0002.00
1,500–2,00030,0002.50
2,000–2,50034,0002.83

Source: ENERGY STAR, Room Air Conditioners. Capacities are calculated for an 8-foot ceiling.

FAQ

What size AC do I need?

For a room, use the ENERGY STAR chart: for example, 450–550 sq ft is 12,000 BTU/hr (1 ton) before adjustments. For a whole house, a rule of thumb in a warm climate like Orange County often lands around 18–25 BTU per square foot, but the right answer is an ACCA Manual J load calculation at your address.

How many BTUs are in a ton?

One ton of cooling is 12,000 BTU per hour. A 3-ton central system is 36,000 BTU/hr.

Can I size a central system from square footage alone?

No. Square footage is a starting point. Windows, insulation, air leakage, duct losses, ceiling height, and your climate’s design temperatures all matter. ENERGY STAR and ACCA expect a Manual J for equipment selection. This tool’s whole-house mode is a planning range only.

What climate zone is Orange County, California?

Orange County is IECC 2021 climate zone 3B (warm-dry). Coastal cities are milder than inland cities such as Anaheim. The California Energy Commission uses its own zone numbers, which often put coastal OC around zone 6 and inland OC around zone 8.

Sources

  • ENERGY STAR, Room Air Conditioners — official sizing chart and sun, occupant, and kitchen adjustments.
  • ACCA Manual J is the professional standard for residential load calculations; ENERGY STAR certified homes require proper ACCA sizing (Manual J / Manual S).
  • IECC 2021 climate zone 3B for Orange County, CA, as shown on IECC/Building America county climate-zone maps (PNNL and related DOE Building America materials).